Relay РЭВ 17
- Automatic flight control systems and autopilots
- Communications, navigation and flight instrumentation
- Engine systems
- Indication and recording systems
- Ice protection and fire protection systems
DESCRIPTION OF THE EQUIPMENT:
The РЭВ17 relay is used in general-purpose and special-purpose electronic communications equipment.
A relay is an electromagnetic device that operates on direct current. It can also operate on high-frequency electromagnetic fields. It’s a coaxial device with two positions, single-stability, and neutral. It has a single switching contact. This device is used to achieve independent time delays. It’s designed for switching signals with a frequency of 1 GHz, when working with coaxial lines with a capacitance of 75 ohms. Relays are used in circuits where it’s necessary to perform certain actions automatically at regular intervals.
The weight of the relay is less than 140 grams.
The power supply is a DC source with a voltage of 27 V.
The type of casing is metal, and it isn’t hermetic.
The РЭВ 17 relay is rated for no more than 50000 switching cycles.
РЭВ17 insulation resistance between live parts and the case:
– In standard climate conditions (when the winding is powered off) – 500 MΩ.
– At the maximum temperature (after the winding has been subjected to working voltage) – 50 MΩ.
– In conditions of high humidity, between the contacts, and between the contacts and the housing, the value is 10 MΩ.
– In conditions of high humidity between the winding wire and the casing – 5 MΩ.
The test variable voltage between the current-carrying components, between the current-carrying components and the housing:
– Under standard climatic conditions – 500 V.
– In conditions of high humidity – 300 V;
– At reduced atmospheric pressure – 200 V.
Minimum service life and storage life of the РЭВ17 relay:
– provided that it is stored in a heated storage facility. It must also be installed in protected equipment, or it must come with spare parts, tools, and accessories. In that case, the warranty period is 12 years.
– Under the condition that it is stored in a heated place, in the packaging provided by the manufacturer, or integrated into the equipment itself – a period of 2 years.
– If stored under a canopy, in the manufacturer’s packaging, or integrated into the equipment, the shelf life is 1 year. – If stored in an open area, integrated into the equipment, the shelf life is also 1 year.